shop by category

Home

Moisture analysers

Moisture analysers

Moisture analysers

Active filters

KERN & SOHN GmbH KERN DAB 100-3 Moisture analyser 1 mg

Moisture analyser with user-friendly graphics display and 15 memories for drying programs

Adjusting program (CAL): For quick setting of the balance's accuracy. External adjusting weight required. Memory: Balance contains memories, e.g. for tare weights, weighing data, item data, PLU etc. Data interface RS-232: To connect the balance to a printer, PC or network GLP/ISO log: with weight, date and time. Only with KERN printers, see Accessories Weighing units: Can be switched to e.g. nonmetric units at the touch of a key. See balance model. Mains part: mains part integrated in the balance. 230V/50Hz Standard type D, if requested also available in standard GB, AUS or USA. Strain gauge: An electrical resistor strip that is glued to an elastic deforming body made of aluminium. As the strain gauge is mechanically deformed its resistance value changes, allowing the measured value to be calculated. 3 years warranty

TECHNICAL DATA

Weighing capacity [Max]110 g
Readability [d]0,001 g
Weighing systemStrain gauge
Temperature [Min] (°C)40 °C
Temperature [Max] (°C)199 °C
Stabilization time3 s
Unitsg, % Humidity, % Dry mass
Reproducibility0,001 g
Linearity± 0,003 g
Readability moisture [d] (%)0,01%
Drying modesStandard drying, Rapid drying, Gentle drying
Switch-off criteriatime controlled, automatic, manual
Input voltage device / power [Max]230 V AC, 50 Hz
Product groupMoisture analyser
€1,125.00 Regular price €1,250.00
KERN & SOHN GmbH KERN DAB 200-2 Moisture analyser 0,01 g

Moisture analyser with user-friendly graphics display and 15 memories for drying programs

Adjusting program (CAL): For quick setting of the balance's accuracy. External adjusting weight required. Memory: Balance contains memories, e.g. for tare weights, weighing data, item data, PLU etc. Data interface RS-232: To connect the balance to a printer, PC or network GLP/ISO log: with weight, date and time. Only with KERN printers, see Accessories Weighing units: Can be switched to e.g. nonmetric units at the touch of a key. See balance model. Mains part: mains part integrated in the balance. 230V/50Hz Standard type D, if requested also available in standard GB, AUS or USA. Strain gauge: An electrical resistor strip that is glued to an elastic deforming body made of aluminium. As the strain gauge is mechanically deformed its resistance value changes, allowing the measured value to be calculated. 3 years warranty

TECHNICAL DATA

Weighing capacity [Max]200 g
Readability [d]0,01 g
Weighing systemStrain gauge
Temperature [Min] (°C)40 °C
Temperature [Max] (°C)199 °C
Stabilization time3 s
Unitsg, % Humidity, % Dry mass
Reproducibility0,01 g
Linearity± 0,03 g
Readability moisture [d] (%)0,05%
Drying modesStandard drying, Rapid drying, Gentle drying
Switch-off criteriatime controlled, automatic, manual
Input voltage device / power [Max]230 V AC, 50 Hz
Product groupMoisture analyser
€1,080.00 Regular price €1,200.00
KERN & SOHN GmbH KERN DBS 60-3 Moisture analyser

Adjusting program (CAL): For quick setting of the balance's accuracy. External adjusting weight required. Memory: Balance contains memories, e.g. for tare weights, weighing data, item data, PLU etc. Data interface RS-232: To connect the balance to a printer, PC or network GLP/ISO log: the balance displays the weight, date and time, regardless of printer connected Weighing units: Can be switched to e.g. nonmetric units at the touch of a key. See balance model. Mains part: mains part integrated in the balance. 230V/50Hz Standard type D, if requested also available in standard GB, AUS or USA. Weighing principle: Electromagnetic force compensation: Coil inside a permanent magnet. For the most accurate weighings

TECHNICAL DATA

Weighing capacity [Max]60 g
Readability [d]0,001 g
Weighing systemSingle-Cell
Temperature [Min] (°C)50 °C
Temperature [Max] (°C)200 °C
Stabilization time3 s
Unitsg, % Humidity, % Dry mass, % ATRO
Reproducibility0,001 g
Linearity± 0,003 g
Readability moisture [d] (%)0,01%
Drying modesStandard drying, Rapid drying, Gentle drying, Drying in levels
Switch-off criteriatime controlled, automatic, manual
Product groupMoisture analyser
€1,650.00
KERN & SOHN GmbH KERN DLB 160-3A Moisture analyser 1 mg

Adjusting program (CAL): For quick setting of the balance's accuracy. External adjusting weight required. Memory: Balance contains memories, e.g. for tare weights, weighing data, item data, PLU etc. Data interface RS-232: To connect the balance to a printer, PC or network GLP/ISO log: with weight, date and time. Only with KERN printers, see Accessories Weighing units: Can be switched to e.g. nonmetric units at the touch of a key. See balance model. Mains adapter: 230V/50Hz in standard version for Germany. On request GB or USA version. Strain gauge: An electrical resistor strip that is glued to an elastic deforming body made of aluminium. As the strain gauge is mechanically deformed its resistance value changes, allowing

TECHNICAL DATA

Weighing capacity [Max]160 g
Readability [d]0,001 g
Weighing systemStrain gauge
Temperature [Min] (°C)35 °C
Temperature [Max] (°C)160 °C
Stabilization time4 s
Unitsg, mg, % rH, % Dry mass
Reproducibility0,001 g
Linearity± 0,003 g
Readability moisture [d] (%)0,01%
Drying modesStandard drying, Rapid drying
Switch-off criteriatime controlled, automatic, manual
Input Voltage110V or 240V, 50-60 Hz
Product groupMoisture analyser
€1,655.00
KERN & SOHN GmbH KERN DLB 160-3A Moisture analyser 110V

Adjusting program (CAL): For quick setting of the balance's accuracy. External adjusting weight required. Memory: Balance contains memories, e.g. for tare weights, weighing data, item data, PLU etc. Data interface RS-232: To connect the balance to a printer, PC or network GLP/ISO log: with weight, date and time. Only with KERN printers, see Accessories Weighing units: Can be switched to e.g. nonmetric units at the touch of a key. See balance model. Strain gauge: An electrical resistor strip that is glued to an elastic deforming body made of aluminium. As the strain gauge is mechanically deformed its resistance value changes, allowing

TECHNICAL DATA

Weighing capacity [Max]160 g
Readability [d]0,001 g
Weighing systemStrain gauge
Temperature [Min] (°C)35 °C
Temperature [Max] (°C)160 °C
Stabilization time4 s
Unitsg, mg, % rH, % Dry mass
Reproducibility0,001 g
Linearity± 0,003 g
Readability moisture [d] (%)0,01%
Drying modesStandard drying, Rapid drying
Switch-off criteriatime controlled, automatic, manual
Input voltage device / power [Max]110 V; 50/60 Hz
Product groupMoisture analyser
€1,655.00