Home

Filter By

Filter By

KRÜSS DR6000 Series

Digital laboratory refractometers DR6000-TF fully automatic

Digital laboratory refractometers DR6000-TF fully automatic

In addition to the Peltier element, the DR6000-TF models have a flow-through cell which, in conjunction with the drying unit, peristaltic pump and autosampler, enables fully automatic operation. The measured value is determined using a CCD sensor.

These refractometers are the ideal solution for manufacturers of flavors, fragrances and essential oils, as well as for the pharmaceutical and beverage industries. They are ideal for routine analysis with high sample volumes, quality and purity control of raw materials and end products, or determination of sugar concentration in juices and soft drinks.

Technical data Refractometer DR6000 series
DR6000-TFDR6100-TFDR6200-TFDR6300-TF
SCALESRefractive index (nD)
Concentration of sucrose, glucose, fructose and invert sugar (%Brix)
User-defined (unlimited)
MEASUREMENT RANGEnD 1.3200-1.5800
0-95 %Brix
nD 1.3200-1.7000
0-95 %Brix
nD 1.32000-1.58000
0-95 %Brix
nD 1.32000-1.70000
0-95 %Brix
MEASUREMENT ACCURACY 1)nD ±0.0001
±0.1 %Brix
nD ±0.00002
±0.02 %Brix
RESOLUTIONnD 0.0001
0.1 %Brix
nD 0.00001
0.01 %Brix
MEASUREMENT PERIOD 3)approx. 4 seconds
MEASUREMENT PRISMSapphire
LIGHT SOURCELED 589 nm
SAMPLE VOLUME/FILLING QUANTITY0.5 ml
COMPONENTS IN CONTACT WITH THE SAMPLESapphire, PTFE and stainless steel
Operation & Device data
OPERATIONStand-alone device (incl. firmware): 7.0 inch capacitive touchscreen, 800 x 480 pixels ;
Operation also possible with PC keyboard, mouse, barcode scanner (several languages)
DATA INTEGRITYFirmware, data recording and storage are compliant with the requirements of 21 CFR Part 11 and EU GMP Annex 11
Conformity with GMP/GLP, pharmacopoeias (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST
ELECTRONIC INTERFACE1x USB, 1x RS-232, 1x ethernet, LIMS
Simple integration into networks (DHCP client) or LIMS
ADJUSTMENTEasy-to-understand, menu-guided adjustment.
Certified, traceable calibration standards available as consumables
Temperature data
TEMPERATURE MEASUREMENTIntegrated Peltier sample temperature control system
TEMPERATURE MEASUREMENT RANGE 2)10-80 °C
TEMPERATURE MEASUREMENT ACCURACY±0,1 °C
TEMPERATURE COMPENSATIONActivatable (ICUMSA or freely definable)
TEMPERATURE MEASUREMENTWith integrated temperature sensor Pt100
TEMPERATURE MEASUREMENT RANGE10-80 °C
TEMPERATURE MEASUREMENT ACCURACY±0,1 °C
TEMPERATURE MEASUREMENT RESOLUTION0,1 °C
Devices basic data
HOUSINGAluminum, powder-coated; protection class: IP20
DIMENSIONS (W x H x D)215 mm x 150 mm x 345 mm
WEIGHT5 kg
OPERATING VOLTAGE90-240 V
POWER CONSUMPTION (measurement mode)40 W
RATED FREQUENCY47-63 Hz

¹) Under normal conditions for measurement refractive index (λ = 589 nm, 20 °C, 1013 hPa, 50 % relative humidity)